Getting these errors in the om log of the server that discovers\monitors our network elements. See below. It looks like the network elements get discovered correctly, as in they show up as certified. They show up in monitor as green, you can get performance data and alerts. These errors are showing up for a lot of the Cisco switches and routers. I did a snmpwalk and the oid that is always failing is in regards to interface errors\discards. Is this a real error? I'm wondering if the Cisco MIB is incorporated properly into scom 2012? Thanks in advance.
Log Name: Operations Manager
Source: Health Service Modules
Date: 8/23/2013 11:21:30 AM
Event ID: 11009
Task Category: None
Level: Error
Keywords: Classic
User: N/A
Computer: xserver.xxx.com
Description:
Error in SNMP GET response from IP Address: 142.160.231.3, Status: noSuchInstance(129).
One or more workflows were affected by this.
OID: .1.3.6.1.2.1.2.2.1.18.10148
Workflow name: System.NetworkManagement.MIB2_Base.NetworkAdapter.HighOutputDiscardRate
Instance name: PORT-1.48
Instance ID: {F0BA409F-374D-31D1-AC46-963ED3D2A46D}
Management group: ops2007
Event Xml:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
<System>
<Provider Name="Health Service Modules" />
<EventID Qualifiers="49152">11009</EventID>
<Level>2</Level>
<Task>0</Task>
<Keywords>0x80000000000000</Keywords>
<TimeCreated SystemTime="2013-08-23T16:21:30.000000000Z" />
<EventRecordID>103734</EventRecordID>
<Channel>Operations Manager</Channel>
<Computer>xxx.xxx.com</Computer>
<Security />
</System>
<EventData>
<Data>ops2007</Data>
<Data>System.NetworkManagement.MIB2_Base.NetworkAdapter.HighOutputDiscardRate</Data>
<Data>PORT-1.48</Data>
<Data>{F0BA409F-374D-31D1-AC46-963ED3D2A46D}</Data>
<Data>142.160.231.3</Data>
<Data>noSuchInstance</Data>
<Data>129</Data>
<Data>.1.3.6.1.2.1.2.2.1.18.10148</Data>
</EventData>
</Event>
lars