Quantcast
Channel: Operations Manager - General forum
Browsing all 11941 articles
Browse latest View live

SCOM datawarehouse

Hi,I am using scom datawarehouse for retrieving server Specification data such as disk, CPU.... monitored in report that i built, i have discovered that scom does not log any data in Datawarehouse for...

View Article


Side x Side Migration - Same Service Accounts

I'm performing a side x side migration from 2007 R2 to 2012 R2.  Is it okay to use my existing 2007 R2 service accounts for my 2012 R2 instance, or should new service accounts be created?

View Article


SCOM 2012 R2 Network monitoring - Probe monitor

Hi, Can anyone let me know how to create probe monitor to monitor temperature and Powesupply. How to get the OIDs for it and what parameters to use.Thanks in AdvacneBharath

View Article

How to change the 'value' parameter for the alert "Transport Categorizer Jobs...

HelloI had an issue with exchange 2010 MP that the alert generated for messaging queue length when it was at 15 and the next generated when the queue length was 5074 and the it generated when the queue...

View Article

SCOM 2012 R2 Cisco Router - WAN Link Bandwith Monitoring

Hi,is it possible to monitor  WAN Links bandwith utilization (between our Branch Offices and our Main Office)  like MRTG with SCOM 2012 R2 ?we have Cisco routers in place and I added them to our...

View Article


SCOM 2012 R2 Design Questions

Hi Guys I wanted to gather some opinions, I wanted to know what the advise was on installing a HA SCOM installation on 2 (and only two) physical servers.1 Server in one Data center and 1 Server in...

View Article

Monitoring Filestream database files

Hello everyone,I've got two MS SQL 2012 databases - each one with three database files. In SCOM 2012 R2 every database file is monitored correctly except the one with file type "FILESTREAM Data".Here...

View Article

SCOM 2012 SP1 - Network Monitoring - Mac addresse in "Path" instead of the...

Hello, I currently facing a "problem" when monitoringnetwork equipment, when displaying a alert , the name of the equipment is not used . Instead scom uses the mac address of the device. Anybody have a...

View Article


Image may be NSFW.
Clik here to view.

Regarding performance widget (performance objects) for custom dashboard

Hi,I'm making a custom dashboard, I'm trying to use the performance widget for a netapp volume, but the performance objects are not available and only see "(All)" on the options (see screenshot).  When...

View Article


updating Management Packs

Hi I am new in SCOM 2012 and I am trying to learn it. I have couple of questions regarding updating management packs.here is the story:1- I have imported some Mps into my SCOM environment so i am...

View Article

Image may be NSFW.
Clik here to view.

SNMP Traps Received are Incorrect

Hello,I am running SCOM 2012 R2 and I have setup SNMP to receive traps from my HP Procurve switches.  All my switches were bought at different times so they have different revisions.  I opened a thread...

View Article

Unable to install Report Viewer 2012

As part of the SCOM console install I need to install Report Viewer 2012. To install Report Viewer 2012 I need to have Microsoft System CLR Types for SQL Server 2012.I have installed all versions of...

View Article

Image may be NSFW.
Clik here to view.

Missing buttons?

Im using SCOM 2012 R2 on Server 2012 R2 and am noticinig some buttons missing when I try to uninstall/repair agents.  There isnt an Uninstall button???  Is this a bug in SCOM 2012 R2 that others are...

View Article


Image may be NSFW.
Clik here to view.

Understanding the alerts and health on the SharePoint 2013 MP

Hi – I am just working on trying to tweak and understand the alerts and health views of the SharePoint 2013 MP. I have it installed successfully (thanks to this forum and blogs – not the guide!) and I...

View Article

Agent Server not reflecting under "Add Group" or " Add Object in SCOM 2012

Hi,Here the Windows Agent server are showing healthy under 'Windows Computer' in Monitoring tab. Also I can view the various objects  like Memory, Logical Disks, System etc under Performance View. Once...

View Article


Exception reading objects

Hi guys,this Exception occurred, after I created a State Widget.Do you know, what this message has to mean, and how I can solve this problem?Here the message:Please provide the following information to...

View Article

Image may be NSFW.
Clik here to view.

Details Widget not working on website

Hi!I justcreated new Dashboard for alerts. It is working great from OpsMgr Console, but when I access it from webpage, no details are displayed. Alerts are shown OK, but no details after clicking an...

View Article


Create Memory Group in SCOM 2012

Hello,I would like to create dynamic groups based on memory capacity to set the threshold for different sizes.Anyone help me to create a group based on memory size?regards,Vijay

View Article

SCOM 2012 R2 EVENT ID 26007 if EVENT ID 31 from...

HI,we have an issue with scom on our Domain Controllers. Every Time we have an Event id 31 from Kerberos-Key-Distribution-Center, Scom Client writes  an Error from a few Monitors into Operations...

View Article

ebola

 So why cant the Band device be used  for Ebola monitoring. Can it be upgraded to measure body temperature  and to notify both the user and the health authorities if the soldier or doctor who has...

View Article
Browsing all 11941 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>