Quantcast
Channel: Operations Manager - General forum
Browsing all 11941 articles
Browse latest View live

ConfigMgr 2007 service failure: SMS_SITE_BACKUP failed to start

Hi allI had a SCOM alert for Backup services failed to start as below, while investigating found all SCCM services were in ‘failed to start status’ .But I did not received any SCOM alert for services...

View Article


How to create RAG Status dashboard in SCOM 2012

HiI want dashboard which should show only RAG status based on %CPU utilization, %Memory utilization and % Free space parameter. How can I do this. When I am creating performance view dashboard then it...

View Article


URL Monitoring Issues

We are using SCOM 2012 to poll 100 URLs.All of the URLs must be polled at 4:30 PM everyday, but only once a day.When we put in all 100 URLs to be polled, and save the monitor at 4:30 PM with 24 hour...

View Article

SCOM 2012 SQL Express with Advanced Services R2 SP1 Compatible?

Hi,This is just a general informational inquiry.Is there a way to have SCOM 2012 run on SQL EXPR with ADV services R2 SP1?If not, can I have my primary Management server run on a server that runs Full...

View Article

Add information to Account Lockout Alert Rule

I have a rule in SCOM which generates alerts for account lockouts in our AD domain. I would like to include additional information when there is a lockout generated from an IIS server.By default the...

View Article


Passing a default parameter to a powershell script

Hello, I wrote a short PS script that gets the parameters of an alert and writes them to a log file.The parameters I pass (via a channel) are:'$Data/Context/DataItem/AlertName$' '$Data[Default='Not...

View Article

Migrate DataWarehouse to new management server scom 2012

hello , i have problem with migrate datawarehouse to new management server. i have scom 2012 and now i install on new server 2012 sp1 (with new name of management server).

View Article

Monitor Windows service using SCOM

Hi ,I want to get confirmation if SCOM2012 SP1 can be used to monitor Windows Service Memory ? As in my case I am having memory leakage in windows service and I need to identify that .If yes can you...

View Article


SCOM to monitor Windows service memory

Hi ,I want to get confirmation if SCOM2012 SP1 can be used to monitor Windows Service Memory ? As in my case I am having memory leakage in windows service and I need to identify that .If yes can you...

View Article


Two distributed app`s with availability and performance monitoring

When i created one distributed application every thing was fine, availability and performance monitors roll-up, and i successfully created service level tracking for this application. But when i...

View Article

SCOM to monitor Windows Service

Hi ,SCOM can monitor process level information (memory/cpu/is your service running/restart if it is not) of a windows service .  But what our experts say is SCOM cannot get the code-level details for...

View Article

Sending syslogs from sccm to remote syslog server?

I'm new to this site; i need help.I want to bring in logs (syslogs) from sccm to my SIEM (remote syslog server). All the documentation i have gone through talks about bringing logs from others sources...

View Article

Some services not monitored

hi there,im using SCOM 2012 SP1 in quite a large environment. everything is working as expected except of one customer whos services arn’t monitored. the strange thing is that everything is green...

View Article


Monitoring HP hardware using SCOM 2007/2012

hello All,We want to monitor hardware of our HP servers without using HP SIM.We want to use our SCOM agents and servers for HP hardware monitoring.Do we have any HP/Third party MP's for same?We have...

View Article

scom does not send notifications anymore

hello, im facing a weird issue with my scom management server. it sends no more notifications. it's true, that it is signaling that the databases are almost full, but, when i see the results of...

View Article


Can System center advice on the memory module issues or on Hardware issues?

Hi,Can System center advice on the memory module issues or on Hardware issues?Your help appreciatedThanks

View Article

SCOM Notifications for both Warning and Critical Alarms

Greetings,There are many situations where one may want a notification channel to run for both the warning and critical state for the same alarm.  A critical piece to this is the transition of an...

View Article


$Data/Context/DataItem/Severity$...and way to change to Descriiptive name,...

Two posts in one day...Still working on the channel formating of an email.The property $Data/Context/DataItem/Severity$ lists the severity ID, 2, 1, or 0.Is there a way to make the...

View Article

Best way to deal with "test" servers in live SCOM environment?

Hi, we have a number of test/dev servers in our live environment that we want to monitor with SCOM to pick up on problems such as disk space and other general problems. We dont have loads of these...

View Article

Should I be installing SCOM 2012 R2 instead of SCOM 2012 SP1 UR2?

We are implementing SCOM 2012. I installed SCOM 2012 SP1 and while googling where to get UR2, I saw results for SCOM 2012 R2? However, I can't find any info on it and even checked to see if Kevin...

View Article
Browsing all 11941 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>