Execute powershell command (new-object -comObject ...) in management pack

Hello everyoneI have a COM Object that want to use it in my management pack. When I write the powershell command "new-object -comObject ... " to create it outside of MP and in a ps1 file it works...

View Article


Do I need a license for Uninterruptible Power Supply?

Hello!I want to monitor some infrastructure devices with SCOM 2012. Tell me please, do I need a management license for devices like:1) UPS (with integrated management modules available by SNMP)2) APC...

View Article


SCOM 2007 (Windows 2003) to SCOM 2012 (Windows 2012)

In our SCOM 2007 R2 as below:1, Only one RMS server with Windows 20032, Only one MS server with Windows 20033, Only one Management group.4, SQL version is SQL Server 2005Our Requirement is to be...

View Article

Issue with Agents in Application DNS domains

I have a confusing scenario. We have a number of servers being monitored that have their DNS in an application domain, not their true AD domain. When installing the SCOM agent it picks up the...

View Article

MSMQ Private Queue Threshold

Hi,I was able to download the latest management pack for MSMQ in SCOM 2012 r2. The server and private queues are visible but I am not sure how to setup the threshold of messages. I would like to first...

View Article


Network Device Monitoring - Discovered devices showing not monitored

I am attempting to discover and monitor our Cisco network devices in SCOM 2012 R2.  I was able to run a recursive discovery and found over 471 devices 2 pending.  When I check the Network Devices view...

View Article

2 SCOM Agents

hi teami have a SCOM server. I have 2 agents instead of one. Can you assist me with removing one of the agents and rerun the agent on all servers. Yes, only servers have SCOM agents installed. I have...

View Article

Error trying to integrate visio 2010 and opsmgr 2012

After following the instructions from Install the Visio 2010 add-in and try fixing the issue with scom-2012-visio-integration-add-in-not and still have no luck. I have uninstalled both visio 2010 and...

View Article


Maintenance Mode on Cluster triggers alerts

Hi,I have a couple of problems that I am seeing with SCOM R21) When I put a physical cluster node under maintenance, it immediately triggers alerts within SCOM about the Cluster resource being offline....

View Article


Eventid 29112 on fresh install OPSMgr 2012R2 with SQL2012

I have performed a fresh install of OpsMgr 2012R2 with SQL 2012. OpsMgr on server1, SQL DB on server2 and SQLDW on server3. Both SQL are installed from same source.Install runs fine, but eventlog keeps...

View Article

purging agentless exception monitoring entries

After turning on client monitoring we have tens of thousands of entries under 'Agentless Exceptin Monitoring -> Error Events' and 'Agentless Exception Monitoring -> System Error Group View' . Is...

View Article

OU Membership not showing for agentless server

In SCOM 2012 R2, I have a group that I set up to dynamically include servers that are in a specific OU. While this is working great for my agent managed servers, I have one that is agentless (managed...

View Article

Availability Report with NO Planned Maintenance Activity

I need to create an Availability Report for my servers, but I would like to exclude planned outages from affecting the availability calculation.  In other words, if the servers were up for the past...

View Article


Putting a SCOM group in maintenance mode.

We're using SCOM 2012 R2 and I've been trying to come up with something that can put a SCOM group in maintenance mode if a specific monitored object in that same group has a critical alert.  I've...

View Article

Maintenance mode exit repeating alerts

Hi,We have a scheduled maintenance window where our servers get patches and security updates. When our SCOM 2012 R2 system exits the maintenance mode it seems to see the maintenance window as a change...

View Article


Gateway unable to connect to Management server

Hi,We are currently having an issue with one of Gateway servers which is not able to connect to RMS server. We had tried re-issuing the Root certificate and the other client certificates as per...

View Article

SCOM Sample Count

I have been tasked with identifying the threshold for both CPU Utilisation and Memory Utilisation on any of our servers that report into SCOM 2007 R2.  SCOM with it's default management pack utilises a...

View Article


SCOM Number of Samples

I have some monitors that generate alerts. When I view the state change events, I see that the number of samples stays the same over a period of days where others increase (as I'd expect if they take a...

View Article

SCOM 2012 SP1 failed to send notifications by IM Channel

Hello, I have a problem with my SCOM 2012 SP1. When it tries to send notification by IM Channel I get the following alert in SCOM:Notification subsystem failed to send notification using device/server...

View Article

SNMP Walk Failed to submit task

hi all, i come across problem when try do SNMP walk on fresh device just discovered. is first time i try monitor network device on scom so any help will be much appreciated.An object of class...